A suspended ceiling brings to mind white tiles in an office. In practice it is one of the most effective acoustic tools in a building: it takes up the largest free surface in the room, does not interfere with use, and can be specified to absorb almost all the sound that hits it.
Below we answer the questions we hear most often from clients: what a suspended ceiling actually is, how it “quietens” a room, what types there are and what to look for in a product datasheet. At the end – where we have installed such ceilings.
What is a suspended ceiling?
A suspended ceiling is a second, lower ceiling plane hung on hangers beneath the structural slab. It consists of a supporting structure (most often a steel grid of profiles) and an infill: tiles, cassettes, panels, slats or a membrane. A void is left between the slab and the ceiling – the so-called ceiling plenum – through which services run: ventilation, cables, sprinklers.
The requirements for suspended ceilings are set out in EN 13964. From an acoustic point of view, however, what matters most is what the infill is made of and how large the void above it is. The same structure can give a quiet, intelligible room or one as reverberant as a stairwell – depending on the tiles.
How does a suspended ceiling absorb sound?
Sound is vibration of the air. When a wave hits a hard surface (concrete, plaster, glass), almost all of it bounces back into the room. The reflections overlap and take a long time to die away – this is reverberation, which makes a hall “boom” and makes it hard to understand a speaker in a conference room.
An acoustic tile works the other way round. It is porous – made of mineral wool, glass wool or a perforated material with a wool backing. The wave penetrates the pores, air molecules rub against the fibres, and the sound energy is converted into a negligible amount of heat. Only a small part of the sound returns to the room.
The void above the ceiling plays an important role. Low sounds have long wavelengths and “pass through” a thin tile; the space behind it acts as an additional absorbing layer. That is why manufacturers quote results for a specific suspension height – e.g. Ecophon Master E reaches αw = 1.00 at a total system depth of 200 mm. A tile glued to the slab absorbs bass noticeably less well.
How to read a ceiling’s acoustic parameters
The basic figure in a product datasheet is the weighted sound absorption coefficient αw. It ranges from 0 (everything is reflected) to 1 (everything is absorbed). Based on it, tiles are divided into absorption classes A to E. Measurement is carried out in a reverberation room according to EN ISO 354, and the class is assigned according to EN ISO 11654.
More on how to read a notation such as “αw = 0.90 (LM)” in our article on the absorption class αw.
The effect in the finished room is verified by measuring reverberation time – we describe it in the article how reverberation time is measured. The required values for classrooms, offices and sports halls, among others, are given in PN-B-02151-4:2015-06.
Scroll horizontally to see all columns
What does an acoustic ceiling really deliver? A simple calculation
Reverberation time can be estimated with Sabine’s formula: T = 0.161 · V / A, where V is the volume of the room and A is the “absorption area”, i.e. the sum of the surface areas multiplied by their absorption coefficients. It is a simplification, but it shows the scale of the change well.
Take a 10 × 8 m room that is 3 m high: V = 240 m³, and the floor, ceiling and walls together have 268 m². If all surfaces are hard (assume α ≈ 0.05), the absorption is 268 · 0.05 = 13.4 m² and the reverberation time is 0.161 · 240 / 13.4 ≈ 2.9 s – speech blurs into noise.
Now we hang a class A ceiling with αw = 0.90. The ceiling alone provides 80 · 0.90 = 72 m² of absorption, and the remaining surfaces 188 · 0.05 = 9.4 m². Together that is 81.4 m², and the reverberation time drops to 0.161 · 240 / 81.4 ≈ 0.5 s. One change – the ceiling – shortens the reverberation almost sixfold.
What types of suspended ceilings are there?
The type of ceiling is matched to the room: acoustic requirements, humidity, risk of impact, access to services and appearance. The most common solutions are:
Modular (tile) ceilings on a visible or concealed grid – mineral wool or glass wool tiles, usually 600 × 600 or 1200 × 600 mm. The best price-to-acoustics ratio and easy access to services. Details in the suspended ceilings offer.
Metal ceilings – cassettes, strips, grids and slats. They absorb sound only when perforated and fitted with a fleece or wool backing; solid sheet metal reflects sound. See metal ceilings.
Free-hanging ceilings – islands, sails and baffles suspended below the slab when the whole ceiling cannot be closed (e.g. with thermally activated concrete or a high, exposed slab). See free-hanging ceilings.
Wooden ceilings – slats, strips and panels; acoustic when they have gaps or perforation and an absorbing layer behind them. See wooden ceilings.
Stretch ceilings with a micro-perforated membrane and wool above it – a smooth, seamless surface with an acoustic function. See stretch ceilings.
Impact-resistant ceilings for sports halls – tiles and grid tested for ball impact according to Annex D of EN 13964. More in the article on ceiling resistance to ball impact and in the sports hall acoustics offer.
Which suspended ceiling for which type of building?
For buildings with an unusual volume or purpose, it is worth starting with an acoustic study – it shows how much absorbing surface is really needed, so you neither overpay nor underestimate. We write about grid corrosion in swimming pools in the article on corrosion resistance classes.
Scroll horizontally to see all columns
Where have we installed acoustic suspended ceilings?
We install acoustic ceilings mainly in Greater Poland and western Poland, but we have also worked in Bydgoszcz, Polkowice and Zakopane. A few examples by type of building:
Sports halls: Babimost, Kostrzyn, Kwilcz, Bydgoszcz – Łuczniczka hall, Szczecin – Szczeciński Dom Sportu and Zakopane – Central Sports Centre.
Swimming pools and leisure centres: Termy Maltańskie in Poznań, AWF swimming pool in Poznań and Recreation Centre in Oborniki.
Churches: in Poznań in Naramowice, in Strzeszyn and the Evangelical Augsburg church, as well as in Gniezno, Janikowo, Międzychód and Wiry.
Culture: the Philharmonic in Szczecin, cultural centres in Września, Witkowo, Międzychód, Międzyrzecz and Podjuchy in Szczecin, and the “Ujście Warty” centre in Chyrzyno.
Offices and retail: in Poznań the Nowy Rynek office building, Galeria Posnania, INEA Park and the Aluplast training centre, and elsewhere Suchy Las, Polkowice and Zakrzewo.
Schools and universities: Tarnowo Podgórne, Zalasewo, the music school in Jankowice and the Biocentrum in Poznań.
Other buildings: PKP railway station in Wolsztyn and cheese dairy in Golęczewo.
Frequently asked questions
What is the difference between a suspended ceiling and an acoustic ceiling?
“Suspended ceiling” describes the method of installation – a plane hung below the slab. An acoustic ceiling is one that absorbs sound. Most acoustic ceilings are suspended ceilings, but not every suspended ceiling is acoustic: unperforated plasterboard or solid sheet metal reflect sound.
Does a suspended ceiling quieten a room?
Yes, if it has tiles with a high absorption class (A or B). It then shortens reverberation and lowers the overall noise level in the room. It does not, however, stop sound passing through the floor or wall from an adjacent room.
What absorption class is needed?
In sports halls, swimming pools, canteens and open-plan offices, class A (αw 0.90–1.00) is usually used. In offices and classrooms, class B is often enough. How much absorbing surface a particular room needs is determined by a reverberation time calculation.
Does the suspension height of the ceiling matter for acoustics?
Yes. The void above the ceiling improves absorption of low frequencies, which is why manufacturers quote αw for a specific system depth, e.g. 200 mm. A tile fitted right against the slab absorbs bass less well than the same tile hung lower.
Can acoustics be improved without replacing the whole ceiling?
Often yes. When the ceiling cannot be replaced, islands and baffles hung beneath the existing slab or wall panels are used. How many are needed follows from an acoustic study.
Is an acoustic ceiling suitable for a swimming pool?
Yes, but you need to choose moisture-resistant tiles and a grid with a suitable corrosion resistance class, because the air above the pool is humid and contains chlorine. We have installed such ceilings at Termy Maltańskie in Poznań and at the Recreation Centre in Oborniki, among others.
Where do you install acoustic ceilings?
Mainly in Greater Poland and western Poland – Poznań, Gniezno, Września, Szczecin, Międzychód and the surrounding areas – but we have also completed projects in Bydgoszcz, Polkowice and Zakopane. The quote is free: just send an enquiry with a floor plan or photos.