Service · Specialist systems
Sports hall acoustics: impact-resistant systems, multi-purpose sports halls
We shorten reverberation in sports halls and gymnasiums: a ceiling and selected walls made from materials that absorb sound and withstand ball impacts — from calculations to installation during the school holidays.
Acoustically, a sports hall is one of the most difficult interiors there is: a large volume, a high ceiling and, above all, huge, hard surfaces — walls, ceiling, glazing, parquet flooring — off which sound bounces repeatedly before it dies away. Anyone who has ever taught a class there knows the result: the whistle gets lost in the reverberation, instructions have to be repeated, and after a few hours the PE teacher loses their voice. This isn't a matter of comfort but of speech intelligibility — and in sport, of safety too, because a player who hasn't heard a signal doesn't react.
The hall isn't just for sport, though. In many schools, it's also where the eighth-grade exam and the Matura (school-leaving exam) take place — exams that shape a pupil's future, and the foreign-language papers include a listening-comprehension section played from a recording. If reverberation blurs the recording, a pupil at one end of the hall hears it worse than one sitting close to the speaker. The seat they're assigned for the exam can then affect their result — and the result, which school they go on to and whether they get into the university of their dreams.
Example projects
Facilities where we have used sports hall acoustics.

2026
Szczeciński Dom Sportu

2023
Sports Hall at the Youth Educational Centre (Młodzieżowy Ośrodek Wychowawczy) in Babimost

2022
Sports Hall at the Primary School in Kwilcz

2020
School and Sports Hall in Cerekwica

2018
Sports hall at the primary school in Kostrzyn

2014
Warm-Up Hall Next to the Łuczniczka Multi-Purpose Arena in Bydgoszcz
Where we apply it
- Sports halls
- Gymnasiums
- Multi-purpose sports and events halls
- Play centres
- Recreational facilities
- Wall panels in the pitch zone
The most common mistake is treating just the ceiling. In a hall, a significant share of reflections travel horizontally, between parallel walls, and that's exactly where flutter echo occurs — the ceiling can't reach it. The most effective layout is three absorbing surfaces set perpendicular to one another: the ceiling plus two walls — the one opposite the stands and one perpendicular to it — lined across a band roughly 0.6 to 3 m above the floor, where most sound is generated and reflected. How much material is needed and where it should go is something we determine with an acoustic report, not “by eye” — so you don't pay for unnecessary metres, or end up with a hall that still booms.
In a sports hall, the acoustics have to survive the ball. An ordinary acoustic ceiling would quickly suffer here, so we use systems with a reinforced panel surface, mounted on a reinforced structure with impact-protection retaining clips. Resistance is tested for the whole set — panels, profiles, hangers and fasteners — in accordance with PN-EN 13964 (Annex D) and DIN 18032-3, in tests where the finished ceiling is struck with a ball; the result is described by classes 1A, 2A and 3A. Reinforcement doesn't come at the expense of acoustics: the best systems hold absorption class A. Our fastest project of this kind — around 1,100 m² of ceiling and 200 m² of wall panels — was completed within two weeks of the winter school break, so pupils returned after the holiday to a finished, quiet hall.
Frequently asked questions
What should you choose — ceiling or walls?
Ideally both, but if priorities are needed, you start with the ceiling and then add selected walls. In a hall, sound bounces between all the hard surfaces, so damping just one leaves the rest “in play”. Picture a rubber ball thrown into a box — as long as the sides are hard, it keeps bouncing endlessly. But line just three surfaces with soft material — the ceiling and two perpendicular walls — and the ball loses its energy almost immediately. Sound behaves the same way: the ceiling plus two well-chosen walls catch most of the reflections and genuinely shorten reverberation, whereas the ceiling alone usually isn't enough.
Which walls should be lined in the hall?
Not all of them are needed — two are key. The best result comes from lining the wall opposite the stands plus one wall perpendicular to it. This arrangement interrupts reflections in both directions (along and across the hall) and eliminates flutter echo, which arises between two parallel, hard walls. Together with the ceiling, this gives three “soft” surfaces set perpendicular to one another — exactly the rubber-ball situation in which sound energy dies away quickly. The walls in the pitch zone must be impact-resistant (class 1A), and we confirm the precise selection and layout with an acoustic report.
Do whole walls need to be lined from floor to ceiling?
No. Wall panels are best installed at the height range where play takes place and people are present — roughly between 0.6 and 3 m above the floor, since that is exactly the band where most sound is generated and reflected. The precise extent, however, depends on the room: the presence and height of stands, the layout of the pitch, or the disciplines the hall is meant to serve. So instead of lining the walls “by eye”, it's always worth having an acoustic report prepared — it lets you optimise the panel area (avoiding overpaying for unnecessary material or underestimating it), place it correctly and genuinely deliver acoustic comfort. We take care of that part ourselves.
Do these systems absorb sound well?
Yes — reinforcement does not come at the expense of acoustics. The best solutions achieve absorption class A (αw up to 1.00), the highest possible. This means a single system combines effective reverberation reduction with full impact resistance.
How does an impact-resistant ceiling differ from a standard acoustic ceiling?
The basis is the same — both absorb sound and shorten reverberation. The difference lies in durability: an impact-resistant system has a reinforced panel surface and a stronger structure (profiles, retaining clips, fasteners), allowing it to withstand ball impacts and other mechanical knocks without damage. An ordinary acoustic ceiling in a sports hall would quickly suffer — here, durability matters just as much as acoustics.
What do classes 1A, 2A and 3A mean?
These are the three impact resistance classes under EN 13964, where 1A is the highest. Class 1A is intended for halls where high-energy balls are used (handball, football, tennis). Class 2A covers lower-energy impacts (e.g. volleyball) and is often sufficient for ceilings hung high up. Class 3A applies to places exposed to occasional impacts — school corridors, common rooms or corrective-gymnastics rooms.
Which class should I choose for my hall?
It depends on the disciplines played, the suspension height and the installation location. In multi-purpose sports halls, ceilings hung below 8 m and wall panels near the pitch should be class 1A; higher up, class 2A is often enough. In school rooms with lower risk, class 3A is used. The division is not rigid, however — it also takes into account whether activities are supervised and whether the building's purpose might change in future. We help select the right class at the design stage.
Is it just the panel that's impact-resistant, or the whole system?
The whole system — and this is crucial. Testing and certification apply to the complete set: panels together with profiles, hangers and connectors. Swapping any element for a “substitute” can reduce the resistance and invalidate the impact-resistance certificate. That's why we install the systems as complete sets, in line with the manufacturer's instructions.
Is it safe — will the panel fall down after an impact?
No — and that's one of the main reasons these systems are used. Retaining clips and impact-protection fasteners hold the panels in place even under a hard ball impact, so they don't come loose from the grid or fall down. This matters especially in buildings with children and heavy use.
How long does installation take in a standard school sports hall?
For a typical school sports hall of up to about 1,000 m², installation usually takes around ten to twenty working days — depending on the system class, the height of the hall, the scope of work on the walls and access to the building. We try to fit in with the school calendar and carry out the work during term breaks. For example, our fastest project of this kind — a hall with around 1,100 m² of ceiling and 200 m² of wall panels — was completed in just two weeks, entirely during the winter school break, so pupils returned after the holiday to a finished, quiet building.
How much do an impact-resistant ceiling and wall panels cost?
The basis of our solutions is the Ecophon Super G system. An impact-resistant ceiling costs from PLN 210/m², excluding VAT, for the material and from PLN 90/m², excluding VAT, for installation — from PLN 300/m², excluding VAT, in total. Wall panels cost from PLN 320/m², excluding VAT, for the material and from PLN 95/m², excluding VAT, for installation — from PLN 415/m², excluding VAT, in total. The final price is determined mainly by: the required impact-resistance class and system variant, the height of the hall and the suspension method, the scope of work on the walls, and access to the building and the completion deadline — for example, the need to fit the work into the school holidays. We prepare the quotation individually, based on the design or an on-site measurement. All prices given are indicative — the final price always depends on the building, the fixing system and the substructure.