For designersFor contractors
Echo in sports halls – how to reduce it effectively
Flutter echo arises between two parallel, hard walls. An acoustic ceiling will not remove it — but it is enough to line one wall of each such pair.
For designers and contractors who hear a “buzzing” in the hall after every clap.
Clap in an empty hall while standing between the side walls. If, instead of a single reflection, you hear a fast, fading rattle, that is flutter echo: sound bounces back and forth between two parallel, hard surfaces and loses very little energy with each reflection.
This phenomenon differs from ordinary reverberation, but it degrades speech intelligibility just the same. The worst part is that it can survive even after a good acoustic ceiling is installed — because it travels horizontally, between the walls, and never touches the ceiling at all.
Work it out: how fast the reflection returns
The time between successive repeats is the round-trip distance divided by the speed of sound: t = 2d / c, where d is the distance between the walls and c ≈ 343 m/s (air, 20 °C).
Scroll horizontally to see all columns
Lining one wall of the pair is enough
Flutter echo needs two hard surfaces facing each other. If one of them absorbs, the loop is broken. In simplified terms: a wall with an absorption coefficient of 0.9 leaves 10% of the energy after each round trip, i.e. −10 dB. A 60 dB drop occurs after 6 round trips — in a hall 18 m wide, that is 6 × 0.105 s ≈ 0.6 s.
A hall has three pairs of parallel surfaces: floor–ceiling, the two long walls, and the two end walls. The floor–ceiling pair is solved by an acoustic ceiling. The other two need panels on one long wall and one end wall — which is also what the commentary to PN-B-02151-4 recommends: sound-absorbing material on each of the three pairs, not on a single surface.
What to watch out for during installation
Install the panels in the height band where people play and speak — that is where most reflections arise. The extent is determined for the specific hall.
Panels within reach of the ball must have proven impact resistance, just like the ceiling.
Large glazed areas are hard surfaces too. If a window faces a bare wall, line that wall.
After installation, clap again in the same spot — the rattle should be gone. We installed the ceiling together with wall claddings in, among others, the sports hall in Kostrzyn.
Frequently asked questions
Will an acoustic ceiling remove the echo in a hall?
It shortens reverberation and removes the flutter between floor and ceiling, but not the flutter between parallel walls. For that you need panels on one wall of each pair.
Do both opposite walls need to be lined?
No. One wall of the pair is enough to break the flutter echo. The other can stay hard, unless the reverberation calculation calls for more material.
What is the difference between echo and reverberation?
Reverberation is the even decay of sound after the source is switched off. Flutter echo is a series of distinct, regular repeats between two surfaces. Reverberation is described by the time T, flutter by the distance between the walls.
Sources
- G. Dal Santo, K. Prawda, V. Välimäki — Flutter echo modeling, DAFx 2022 (t_r = 2d / c, flutter band)(opens in a new tab)
- Speed of sound — speed of sound in air at 20 °C ≈ 343 m/s(opens in a new tab)
- Ecophon — Polish Standard PN-B-02151-4:2015-06. Explanations and commentary (placement of materials in sports halls)(opens in a new tab)