For designers
5 steps to perfect acoustics in a sports hall
The acoustics of a new hall are cheapest to settle at the design stage. Five steps: volume, reverberation target, absorption area, placement and impact resistance class — with a calculation showing how the 5000 m³ threshold works.
For architects and designers leading the design of a new sports hall or gymnasium.
In the design of a new hall, acoustics cost the least: you only need to choose well the materials you have to buy anyway. In a finished building, the same result requires extra work, scaffolding and a break in use.
Below are five steps in the order in which decisions are made. Each produces a number you can check before tender.
Steps 1–3: volume, target, absorption area
Step 1: the volume V sets the limit from PN-B-02151-4: up to 5000 m³ the reverberation time must not exceed 1.5 s, above that 1.8 s. Step 2: the limit applies in every octave band from 250 to 4000 Hz, in the finished hall, with no people. Step 3: the required absorption area from the Sabine formula, A = 0.161 × V / T.
Let us compare two halls with an 18 × 9 m cross-section that differ in length:
Scroll horizontally to see all columns
Step 4: placement
Absorption must not be concentrated on a single surface. In a cuboid hall, sound-absorbing material should appear on each of the three pairs of parallel surfaces. A practical rule of thumb is around 70–80% of the ceiling and 10–20% of the walls with a material of αw ≥ 0.9. Two parallel bare walls create flutter echo even when the average reverberation is within the limit.
In the 125 Hz band the absorption is usually the most lacking. A suspended ceiling with an air cavity absorbs best there, so it is worth allowing space for it in the cross-section. The calculation is done band by band using the data of the specific product — we explain the general αw index in the tip on the αw absorption class.
Step 5: impact resistance class and reaction to fire
The impact resistance class (1A, 2A, 3A per PN-EN 13964, annex D) is entered in the specification for the ceiling and for wall panels within ball range. The whole assembly is tested, so the specification names the system, not just the tile.
Example: Ecophon Super G Plus A and Super G B are class 1A, Super G A is 2A and 3A. All three have absorption class A. The Super G A core has a reaction to fire of A2-s1,d0 per PN-EN 13501-1.
Matching the class to disciplines and suspension height is described in our sports hall acoustics offer, and we carry out the full calculation as part of an acoustic study.
Frequently asked questions
Is the Sabine formula enough for design?
For a first estimate, yes. In a large hall with unevenly distributed material the result can deviate from reality, so for larger facilities a computer simulation is also used, and a measurement is always taken at the end.
Do stands and spectators count toward the absorption?
Not for the requirement: the limit applies to the hall without people. Permanently installed seats count as furnishings, but their absorption must be taken from the manufacturer's data, not estimated.
Is absorption class A on the ceiling enough?
The class alone is not enough. What counts is the product of area and coefficient, placement on three pairs of surfaces, and absorption in the low bands. Class A over too small an area will not meet the requirement.
Sources
- Ecophon — Polish Standard PN-B-02151-4:2015-06. Explanations and commentary (requirements and guidance for sports halls)(opens in a new tab)
- Ecophon Super G — variants and impact resistance classes (EN 13964, annex D)(opens in a new tab)
- Ecophon Super G A — product datasheet (2024-05-16): reaction to fire, impact classes(opens in a new tab)